K-Tronix Electronics Repair
Detailed Service Report
Customer: Mark Rozett
Unit: KLH Amplifier
Model: 62U6 - E112521
Invoice: SQ8351075
Reported Issue
Customer reported the unit would only emit a 400 Hz hum when powered on, with no audio output.
Diagnostics & Findings
Initial testing confirmed the amplifier powered on but remained stuck in protection. The protection relay would not switch out of protection, preventing normal output. Low-voltage supply testing showed the 15 V regulation section was out of specification, contributing to instability in the protection/preamp supply.
Further inspection revealed a welded relay condition on one channel and an additional failure in the relay drive / protection support components.
Work Performed
- Replaced all electrolytic capacitors on the power supply board
- Identified relay fault: protection relay contact welded on one channel
- Confirmed protection circuit was not releasing (no relay switching out of protection)
- Tested 15 V rails and measured +16 V and -14 V (out of specification)
- Tested 15 V biased/steering diodes and found them out of specification
- Installed +12 V and -12 V regulators to replace the out-of-spec 15 V biasing network, reducing thermal stress and preventing the preamp section from running excessively hot
- Protection still did not release; traced fault to the diode across the relay coil
- Found relay coil diode failed; replaced with a standard rectifier diode
- After diode replacement, protection released normally and audio output was restored
Testing & Verification
- Load-tested at 2 ohms for 1 hour
- Heat dissipation: within specification during full-duration testing
- Frequency response: within specification
Current Assessment
The amplifier is now operating normally. The protection circuit releases correctly, relay operation is normal, and stable audio output has been verified under load.
Parts & Cost Summary (All-In)
| Labor – Power Supply Rebuild & Protection Circuit Repair | $156.50 |
| Parts – Power Supply Capacitors, Regulators, Relay Diode | $38.50 |
| Bench / Diagnostic Fee Credit | ($89.00) |
| Return Shipping – USPS (11 lbs) | $8.38 |
| Total (All-In) | $114.38 |
Shipping: Return shipping via USPS, package weight approximately 11 lbs. Shipping cost is included in the total above.
Payment
You can submit payment using the link below.
Service Status
- ✔ Power supply board rebuilt (capacitors replaced)
- ✔ Low-voltage regulation corrected (±12 V regulators installed)
- ✔ Relay coil diode replaced
- ✔ Protection circuit functioning correctly
- ✔ Load tested and verified within spec
- ✔ Repair completed
Important Notes
- Customer contact details (email/phone) are intentionally excluded from this report for privacy
- Return shipping via USPS ($8.38) is included in the total
- All measurements and results reflect bench testing at the time of service
Thank you for choosing K-Tronix Electronics Repair.
Text messaging is the fastest way to reach me for updates or questions.